igbs писал(а):
Во, блин, а мне их проходить приходится постоянно, ну почти каждый месяц. Так что пишите если есть вопросы! :wink:
Есть спорные ответы на вопросы - нужна консультация
? TPM is implemented in Dell servers as:
** Hardware
Wetware
** Software
Firmware
----------------------------------------------------------
? Choose All That Apply Which of the following are possible causes of the PowerEdge T105 server not retaining the configuration settings at system boot?
The system power button has been engaged
The system was not shutdown correctly
** NVRAM_CL jumper is currently enabled
** Defective coin-cell CMOS battery
можеть быть еще и The system was not shutdown correctly?
------------------------------------------------------------
? After servicing a PowerEdge T300 system, you notice that the LCD is blinking blue. What should you do to address this system's behavior?
Reseat all components you replaced
Tell the customer the system is working properly
** Take the system out of the system ID state and ensure there are no error messages on the system LCD.
Нужно ли Tell the customer the system is working properly?
--------------------------------------------------------------
? Multiple Choice: A customer says that when he turns on his system he gets the following error on POST, “Alert! Redundant memory disabled! Memory configuration does not support redundant memory.” Which one of the options below is a possible cause of this error message?
A spare rank event occurred during the previous boot.
Faulty or improperly installed memory modules.
The memory configuration does not support node interleaving. The system will run but with reduced functionality.
**Redundant memory was set to enable in CMOS, but the current configuration does not support redundant memory
Может еще и Faulty or improperly installed memory modules?.
---------------------------------------------------
? Choose All That Apply A customer contacts Enterprise support stating that his system reports a E1A1C LCD status message on his PowerEdge R905 system. What online resources can you use to find what the error message means?
** Support.dell.com
Tell the customer that error message is normal
Dcse.dell.com
Может еще и Dcse.dell.com
--------------------------------------------------------
? Choose All That Apply Which of the following are required actions when removing a optical drive from the PowerEdge T105?
Push the sliding plate lever towards the base of the computer.
**Remove the computer cover.
Rotate the hard-drive carrier to the service position.
**Remove the front bezel assembly.
Нужно ли Push the sliding plate lever towards the base of the computer?
-----------------------------------------------------------
? Multiple Choice: Which diagnostic indicator on the PowerEdge T605 will help troubleshoot issues during POST?
BIOS status messages
LCD status messages
Quad pack diagnostic LEDs on the back of the system
Неуверен BIOS status messages или LCD status messages?
--------------------------------------------------------------
? Multiple Choice: What RAID levels are supported by PERC6 controllers?
0, 1, 6, and 60
0, 1, 5, 10 and 50
0, 1, 5, 6, 10, 50, and 60
0, 1, 5, and 10
Разные PERC6 по разному 0, 1, 5, and 10 или 0, 1, 5, 6, 10, 50, and 60
----------------------------------------------------------------
? Multiple Choice: Stephanie wants to install an optional DRAC5 card on her PowerEdge R805. She wants to know what slot to install the card in. Where should it be installed?
Slot 1
Slot 2
Slot 3
RAC_CONN1 and RAC_CONN2 connectors on the system board.
По документации вроде это RAC_CONN1 and RAC_CONN2 connectors on the system board, но в вопросе "what slot to install" сталобыть ответ - slot 1 или 2 или 3